{"id":138,"date":"2015-02-08T17:56:45","date_gmt":"2015-02-08T17:56:45","guid":{"rendered":"http:\/\/www.the-regs.co.uk\/blog\/?p=138"},"modified":"2015-02-08T17:56:45","modified_gmt":"2015-02-08T17:56:45","slug":"bond-this-or-not","status":"publish","type":"post","link":"https:\/\/the-regs.co.uk\/blog\/?p=138","title":{"rendered":"Bond This or Not?"},"content":{"rendered":"<p>Let&#8217;s have a look at a real world situation.<\/p>\n<p>A simple one really but let&#8217;s have a look at some of the Wiring Regulations that may apply.<\/p>\n<p>A three story steel scaffold is being built on the outside of a building to complete some renovation work. There will be walkways and working gantries and as it&#8217;s all sheeted off from the public it will be lit by temporary lighting. The workforce will be using power tools and will need supplies for this. The building is supplied using a TN-C-S earthing system.<\/p>\n<p>Does the steel scaffold need bonding to the main earthing system of the building?<\/p>\n<p>The first place to look is in&#8230; <\/p>\n<p><strong>Part 7: Section 704 Construction and Demolition Site Installations<\/strong><\/p>\n<p>You&#8217;ll see from 704.1.1 (ii) that this section applies to this installation.<\/p>\n<p>Also as we are going to supply the lights and any power tools from the building then <strong>Regulation 704.411.3.1<\/strong> will apply. This states that a PME earthing facility shall not be used unless all extraneous conductive parts are connected to the main earth terminal.<\/p>\n<p>Is the scaffold an extraneous conductive part? See Part 2: Definitions<\/p>\n<p>So in short &#8216;Yes&#8217; and see Regulation 544.1.1 for the size of the main protective bonding conductor, for a TN-C-S look at Table 54.8 usually supply neutral <35mm so 10mm would suffice in this instance.\n\nOther things to consider would also be in Section 704...\n\n704.41 (i) 'reduced low voltage' 110v protection against electric shock re hand held electrical equipment.\n704.52 Wiring systems - re cable positioning and type used for the lighting and power supplies.\n\nAll based upon information in the current 17th Edition of the IET Wiring Regulations BS7671:2008+A3:2015 - The 'yellow' book.\n<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Let&#8217;s have a look at a real world situation. A simple one really but let&#8217;s have a look at some of the Wiring Regulations that may apply. A three story steel scaffold is being built on the outside of a building to complete some renovation work. There will be walkways and working gantries and as&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[11],"tags":[],"class_list":["post-138","post","type-post","status-publish","format-standard","hentry","category-real-world-applications","th-blog blog-single has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Bond This or Not? - the-Regs : BS7671 18th Edition Online Training<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/the-regs.co.uk\/blog\/?p=138\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Bond This or Not? - the-Regs : BS7671 18th Edition Online Training\" \/>\n<meta property=\"og:description\" content=\"Let&#8217;s have a look at a real world situation. A simple one really but let&#8217;s have a look at some of the Wiring Regulations that may apply. A three story steel scaffold is being built on the outside of a building to complete some renovation work. There will be walkways and working gantries and as...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/the-regs.co.uk\/blog\/?p=138\" \/>\n<meta property=\"og:site_name\" content=\"the-Regs : BS7671 18th Edition Online Training\" \/>\n<meta property=\"article:published_time\" content=\"2015-02-08T17:56:45+00:00\" \/>\n<meta name=\"author\" content=\"the Regs Guy\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@theregsguy\" \/>\n<meta name=\"twitter:site\" content=\"@theregsguy\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"the Regs Guy\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?p=138#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?p=138\"},\"author\":{\"name\":\"the Regs Guy\",\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/#\\\/schema\\\/person\\\/0d7feabc48e1ab05b0c346e599ea65cf\"},\"headline\":\"Bond This or Not?\",\"datePublished\":\"2015-02-08T17:56:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?p=138\"},\"wordCount\":216,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/#organization\"},\"articleSection\":[\"Real World Applications\"],\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?p=138#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?p=138\",\"url\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?p=138\",\"name\":\"Bond This or Not? - the-Regs : BS7671 18th Edition Online Training\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/#website\"},\"datePublished\":\"2015-02-08T17:56:45+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?p=138#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?p=138\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?p=138#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Bond This or Not?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/\",\"name\":\"the-Regs.co.uk 18th Edition Online Training Specialist\",\"description\":\"BS 7671: 18th Edition Wiring Regulations - Study when you want and pass your exam  when you&#039;re ready...\",\"publisher\":{\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/#organization\",\"name\":\"the-Regs : BS7671 18th Edition Online Training\",\"url\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/the-regs.co.uk\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/favicon-192x192-1.png?fit=192%2C192&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/the-regs.co.uk\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/favicon-192x192-1.png?fit=192%2C192&ssl=1\",\"width\":192,\"height\":192,\"caption\":\"the-Regs : BS7671 18th Edition Online Training\"},\"image\":{\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/theregsguy\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/#\\\/schema\\\/person\\\/0d7feabc48e1ab05b0c346e599ea65cf\",\"name\":\"the Regs Guy\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f10b538b4ce6fdea13c84ac1ce266ae912ec071c6775b6ce8df5fdad3ac24bb0?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f10b538b4ce6fdea13c84ac1ce266ae912ec071c6775b6ce8df5fdad3ac24bb0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/f10b538b4ce6fdea13c84ac1ce266ae912ec071c6775b6ce8df5fdad3ac24bb0?s=96&d=mm&r=g\",\"caption\":\"the Regs Guy\"},\"description\":\"A professional qualified electrician with nearly forty years of under paid, hard work within the electrical installation industry. I've also been a successful electrical installation tutor since 2008. Delivering both City &amp; Guilds \\\/ EAL level 3 courses including \\\"18th Edition Wiring Regulations, Inspection &amp; Testing (initial verification and periodic inspection, testing and reporting), Building Regulations, PAT and Part P etc.\\\" both in the private sector and local FE colleges. I've also been running my own training center since 2015. See www.waybrite.co.uk\",\"sameAs\":[\"http:\\\/\\\/www.the-regs.co.uk\"],\"url\":\"https:\\\/\\\/the-regs.co.uk\\\/blog\\\/?author=1\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Bond This or Not? - the-Regs : BS7671 18th Edition Online Training","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/the-regs.co.uk\/blog\/?p=138","og_locale":"en_GB","og_type":"article","og_title":"Bond This or Not? - the-Regs : BS7671 18th Edition Online Training","og_description":"Let&#8217;s have a look at a real world situation. A simple one really but let&#8217;s have a look at some of the Wiring Regulations that may apply. A three story steel scaffold is being built on the outside of a building to complete some renovation work. There will be walkways and working gantries and as...","og_url":"https:\/\/the-regs.co.uk\/blog\/?p=138","og_site_name":"the-Regs : BS7671 18th Edition Online Training","article_published_time":"2015-02-08T17:56:45+00:00","author":"the Regs Guy","twitter_card":"summary_large_image","twitter_creator":"@theregsguy","twitter_site":"@theregsguy","twitter_misc":{"Written by":"the Regs Guy","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/the-regs.co.uk\/blog\/?p=138#article","isPartOf":{"@id":"https:\/\/the-regs.co.uk\/blog\/?p=138"},"author":{"name":"the Regs Guy","@id":"https:\/\/the-regs.co.uk\/blog\/#\/schema\/person\/0d7feabc48e1ab05b0c346e599ea65cf"},"headline":"Bond This or Not?","datePublished":"2015-02-08T17:56:45+00:00","mainEntityOfPage":{"@id":"https:\/\/the-regs.co.uk\/blog\/?p=138"},"wordCount":216,"commentCount":0,"publisher":{"@id":"https:\/\/the-regs.co.uk\/blog\/#organization"},"articleSection":["Real World Applications"],"inLanguage":"en-GB","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/the-regs.co.uk\/blog\/?p=138#respond"]}]},{"@type":"WebPage","@id":"https:\/\/the-regs.co.uk\/blog\/?p=138","url":"https:\/\/the-regs.co.uk\/blog\/?p=138","name":"Bond This or Not? - the-Regs : BS7671 18th Edition Online Training","isPartOf":{"@id":"https:\/\/the-regs.co.uk\/blog\/#website"},"datePublished":"2015-02-08T17:56:45+00:00","breadcrumb":{"@id":"https:\/\/the-regs.co.uk\/blog\/?p=138#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/the-regs.co.uk\/blog\/?p=138"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/the-regs.co.uk\/blog\/?p=138#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/the-regs.co.uk\/blog"},{"@type":"ListItem","position":2,"name":"Bond This or Not?"}]},{"@type":"WebSite","@id":"https:\/\/the-regs.co.uk\/blog\/#website","url":"https:\/\/the-regs.co.uk\/blog\/","name":"the-Regs.co.uk 18th Edition Online Training Specialist","description":"BS 7671: 18th Edition Wiring Regulations - Study when you want and pass your exam  when you&#039;re ready...","publisher":{"@id":"https:\/\/the-regs.co.uk\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/the-regs.co.uk\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/the-regs.co.uk\/blog\/#organization","name":"the-Regs : BS7671 18th Edition Online Training","url":"https:\/\/the-regs.co.uk\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/the-regs.co.uk\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/the-regs.co.uk\/blog\/wp-content\/uploads\/2025\/10\/favicon-192x192-1.png?fit=192%2C192&ssl=1","contentUrl":"https:\/\/i0.wp.com\/the-regs.co.uk\/blog\/wp-content\/uploads\/2025\/10\/favicon-192x192-1.png?fit=192%2C192&ssl=1","width":192,"height":192,"caption":"the-Regs : BS7671 18th Edition Online Training"},"image":{"@id":"https:\/\/the-regs.co.uk\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/theregsguy"]},{"@type":"Person","@id":"https:\/\/the-regs.co.uk\/blog\/#\/schema\/person\/0d7feabc48e1ab05b0c346e599ea65cf","name":"the Regs Guy","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/f10b538b4ce6fdea13c84ac1ce266ae912ec071c6775b6ce8df5fdad3ac24bb0?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f10b538b4ce6fdea13c84ac1ce266ae912ec071c6775b6ce8df5fdad3ac24bb0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f10b538b4ce6fdea13c84ac1ce266ae912ec071c6775b6ce8df5fdad3ac24bb0?s=96&d=mm&r=g","caption":"the Regs Guy"},"description":"A professional qualified electrician with nearly forty years of under paid, hard work within the electrical installation industry. I've also been a successful electrical installation tutor since 2008. Delivering both City &amp; Guilds \/ EAL level 3 courses including \"18th Edition Wiring Regulations, Inspection &amp; Testing (initial verification and periodic inspection, testing and reporting), Building Regulations, PAT and Part P etc.\" both in the private sector and local FE colleges. I've also been running my own training center since 2015. See www.waybrite.co.uk","sameAs":["http:\/\/www.the-regs.co.uk"],"url":"https:\/\/the-regs.co.uk\/blog\/?author=1"}]}},"jetpack_featured_media_url":"","jetpack_shortlink":"https:\/\/wp.me\/p32IMi-2e","jetpack_sharing_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/the-regs.co.uk\/blog\/index.php?rest_route=\/wp\/v2\/posts\/138","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/the-regs.co.uk\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/the-regs.co.uk\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/the-regs.co.uk\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/the-regs.co.uk\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=138"}],"version-history":[{"count":0,"href":"https:\/\/the-regs.co.uk\/blog\/index.php?rest_route=\/wp\/v2\/posts\/138\/revisions"}],"wp:attachment":[{"href":"https:\/\/the-regs.co.uk\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=138"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/the-regs.co.uk\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=138"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/the-regs.co.uk\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=138"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}